alarm intergrator, ywa10

For full specification Click Here

Often in the design of a control system the requirement to provide a "common" alarm signal to say drive an audible alarm or signal a BMS system is required. However, it is sometimes required that after an alarm input signal is received the output relay is cancelled, thus say silencing an audible even if the alarm input is still present, but also with an alarm contact still to remain to give silent indication. The YWA10 achieves this function. The YWA10 is only available in 24VACDC input voltage. In all cases the input signals must be derived from the same source, with AC versions also derived from the same phase. The integral electronics ensures that each input is electrically isolated from each other, thus preventing feedbackfrom occurring between inputs

10 INPUT, TWIN OUTPUT, MUTABLE & REPEATABLE alarm module YWA10
YWA9, YWA15, Alarm Integrator, ywricd

For full specification Click Here

Often in the design of a control system the requirement to provide a "common" alarm signal to say drive an audible alarm or signal a BMS system is required. Alarm integrators are single modules available in a number of input ways. The integral electronics ensures that each input is electrically isolated from each other, thus preventing feedback from occurring between inputs. This construction enables a single unit to effectively monitor many different circuits and/or sensors and provide a common alarm output. Indicator lamps may also be connected to each input to show and display the alarm source. To increase the number of alarm ways units can be linked together to facilitate this, the alarm output contacts will require to be wired out in parallel from each unit. The alarm output is a volt free relay output. The YWRICD is a 1C/O output, whilst the YWA9 and YWA15 is a 1N/O output. The alarm integrators are available in various input voltages. However, a mix of input voltages on one unit is not possible and in all cases the input signals must be derived from the same source, with AC versions also derived from the same phase. The alarm integrators use very high voltage tolerant components, such as avalanche diodes. Avalanche diodes are especially suitable for withstanding high voltage as the construction is a diode and varistor combined.

Alarm Integrator ywricd ywa9 ywa15
Alarm Panels Oleno, annunciator panels, indicating panel, diode alarm panel, group alarm, F2000, FCI10, FC-I10, FCD10, FC-D10, FC, FC-, FCDI10, FC-DI10, FC-LKM10, FCLKM10, FC-LKS10, FCLKS10

For full specification Click Here
Indicating Panel
 Description - Indicating panel for 10 indication positions using make contacts. Supply voltage 24 VAC/DC.

Diode Alarm Panel
 Description - Diode alarm panel for 10 positions. Available for 10 alarm positions or 5 alarm and 5 indicating positions. Optional combinations supplied on request. Without memory and flashing functions. Inputs must be from making contacts.
Supply 24 VAC/DC.

Group Alarm Annunciator Panel
 Description
A master panel, used individually or in combination with a number of slave panels (max 100). The units are supplied with 10 alarm positions. Up to 1010 alarm positions possible. Supply 24 VAC/DC.
Alarm Panels Oleno
Lamp Test, YWAD, filament, neon lamp, test module

For full specification Click Here

The limited service life of filament signal lamps often necessitates regular testing, as the indication of a defective lamp may not be immediately recognised. The YWAD lamp test module is a Din rail mounted 11 way lamp test module, the extra input terminal “C” is the Lamp Test input. For more than 11 ways a number of units can be linked together via the “C” input terminal. The lamp test module uses very high voltage tolerant components, such as avalanche diodes. Avalanche diodes are especially suitable for withstanding high voltage as the construction is a diode and varistor combined.

filament & neon lamp test module
Flashing Beacons, PSD,

For full specification Click Here
Our Pulsed Beacons utilise filament lamps, together with entirely solid-state pulser circuits, removing the nuisance of relay noise and replacement. Pulsed beacons allow an extended operational life over a wide range of ambient conditions.
Flashing Beacons
Lamp Test, ywacd, led,

For full specification Click Here

The YWACD is an 8 way lamp test module designed for use with modern LED based indicator lamps. Filament lamp test modules utilise diodes and only allow a half cycle to pass which invariably is not sufficient to strike a LED. The new YWACD is constructed in a manner that allows the full potential to pass, gives full isolation per lamp circuit and at the same time gives full back feed protection. The YWACD is designed to save on wiring time where "lamp test" is called for in specifications and cable congestion on crowded doors.

LED LAMP TEST MODULE. ywacd
led

For full specification Click Here

High intensity LEDs with the control panel builder in mind, being unique at this size with screw terminals.  Installation is simple and cost effective, a smart chrome bezel is first fitted to the panel via an 8mm drilled hole and secured with a hexagonal lock nut.  The lamp body houses a 5mm high intensity LED which is then pushed into the bezel assembly and can be rotated on the already secured bezel to any convenient angle.

MINIATURE PANEL MOUNTED LEDs WITH SCREW TERMINALS
11wa8, Alarm Integrator,

For full specification Click Here
Often in the design of a control system the requirement to provide a “common” alarm signal to say drive an audible alarm or signal a BMS system is required.
Alarm integrators are single modules available in a number of input ways. The integral electronics ensures that each input is electrically isolated from each other, thus preventing feedback from occurring between inputs. This construction enables a single unit to effectively monitor many different circuits and/or sensors and provide a common alarm output. Indicator lamps may also be connected to each input to show and display the alarm source. To increase the number of alarm ways units can be linked together to facilitate this, the alarm output contacts will require to be wired out in parallel from each unit.
The alarm output is a volt free relay output. The 11WA8 has 1N/O output.
The alarm integrators are available in various input voltages. However, a mix of input voltages on one unit is not possible and in all cases the input signals must be derived from the same source, with AC versions also derived from the same phase. The alarm integrators use very high voltage tolerant components, such as avalanche diodes. Avalanche diodes are especially suitable for withstanding high voltage as the construction is a diode and varistor combined.
plug in alrm intergrator 11wa8
Alarm Integrator, ywa5

For full specification Click Here

Often in the design of a control system the requirement to provide a "common" alarm signal to say drive an audible alarm or signal a BMS system is required. However, it is sometimes required that after an alarm input signal is received the output relay is cancelled, thus say silencing an audible even if the alarm input is still present. The YWA5 achieves this function. The YWA5 is available in various input voltages. However, a mix of input voltages on one unit is not possible and in all cases the input signals must be derived from the same source, with AC versions also derived from the same phase. The integral electronics ensures that each input is electrically isolated from each other, thus preventing feedback from occurring between inputs. The YWA5 use very high voltage tolerant components, such as avalanche diodes. Avalanche diodes are especially suitable for withstanding high voltages

REPEATING ALARM INTEGRATORS . ywa5
Sonartone audible alarms, buzzers, sounders, SX01-428, SY01-428, SC01-428, SC03-115, SC03-250, SP03-250

For full specification Click Here
Sonartone rear panel mounting Audible Alarm are inexpensive, rugged, trouble free warning device that cannot be ignored. They produce a penetrating sound, the volume of which can be varied by adjusting the supply voltage. The
models available produce increased audible awareness with single or multitone types operating from AC or DC supplies.
Sonartone Audible Alarms