Your Search returned 10 Results In 0.002 seconds
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Single Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

1 Pole C & D Type MCBs
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Double Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

2 Pole C & D Type MCBs
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Triple Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

3 Pole C & D Type MCBs
trend low coil consumption relays, Wafer. 41F, slim line, miniture, relays, relay, 41

For full specification Click Here

DIN RAIL MOUNTED WAFER RELAYS 6MM WIDE, 
SPCO & DPCO PLUG IN RELAYS 15MM WIDE 
VERSIONS WITH BUILT IN TEST & LED INDICATION, 
AC & DC COIL VOLTAGES AVAILABLE 
LOW COIL CONSUMPTION 12VDC & 24VDC RELAYS, 
CHOICE OF SOCKETS, 
RANGE OF ACCESSORIES

41F-1Z-C2-x-xxx Wafer style relays
Connecting Busbar, fork type, pin type, busbar, bus bar,

For full specification Click Here
Nortonics Foxtam Connecting Busbar comes in two types:

 Pin Type
1, 2 3 phase solid copper conductors with pin attachments for connection of NORM modular components e.g. MCB’s and RCD’s.

 Fork Type
1, 2 3 phase solid copper conductors with fork attachments for connection of NORM modular components e.g. MCB’s and RCD’s.
Connecting Busbar
Contactors

For full specification Click Here

For information regarding contactors please contact our office on +44 (0)1276 25858

CONTACTORS
Fuse Holders, HSC, VLC10, VLC14, VLC22, 10x38mm, hsc-3810,eti

For full specification Click Here

DIN RAIL MOUNTED FUSE HOLDERS VLC10 (10x38mm) max 32Amp (previously called HSC-3810) VLC14 (14x51mm) max 50Amp VLC22 (22x58mm) max 100Amp 1,2 & 3 Pole Type: VLC10 for fuse links 10x38mm, max operational current 32 Amps @ 690VAC Rated making & breaking capacity: 75 Amps Type: VLC14 for fuse links 14x51mm, max operational current 50 Amps @ 690VAC Rated making & breaking capacity: 150 Amps Type: VLC22 for fuse links 22x58mm, max operational current 100 Amps @ 690VAC Rated making & breaking capacity: 150 Amps

Fuse Holders
Push Buttons, switches, key switches, selector switches, emergancy stop box, AU318E, V318E, terminalsandpushbuttons

For full specification Click Here

A robust, high quality range of pushbuttons, selector switches, key switches and emergency stop stations. All to IP65 protection rating.

Push Buttons
RCBOs, tcu, KZS2M, KZS 2M, rcd, mcb busbar, eti

For full specification Click Here

RCBOs combined MCB/RCD two pole. Providing the combined advantage of protection against earth leakage faults with short-circuit protection.

RCBOs Combined MCB/RCD Two Pole
terminals, earth terminals, terminal blocks, common terminal blocks, double bar, quad bar, terminalsandpushbuttons

For full specification Click Here

Din Rail Mounted Terminals A quality range of din rail mounted terminals suitable for "G" rail and "Top Hat" rail both shallow and deep. Available in 2.5mm, 4mm, 6mm, 10mm, 16mm, 35mm and 70mm. The material is PA68VOT110 and the standard colour is grey RAL7035, however on request blue RAL5015 is available. All terminals are CE marked. Common Terminal Blocks Available in three different formats and each format with three permitations. All units are constructed in the same way with brass bars with steel screws set into a poliammide bodywith a transparent policarbonate removable cover. All units can be mounted directly onto top hat din rail or screwed directly to a chassis plate.

Terminals