Your Search returned 3 Results In 0.000 seconds
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Single Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

1 Pole C & D Type MCBs
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Double Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

2 Pole C & D Type MCBs
Single Pole C & D Type, MCB, circuit breaker, eti,

For full specification Click Here

Triple Pole Miniature Circuit Breakers. ETIMAT 10 MCBs are produced according to the latest international standards EN60898, IEC60898 and IEC60947-2. These MCBs are for protection and control of circuits against overloads and short circuits in commercial and industrial applications. Characteristic C is recomended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recomended for heavy industrial applications where very high starting effects are expected, e.g. motors starting under load. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 10 to 20 x In.

3 Pole C & D Type MCBs