Your Search returned 11 Results In 0.000 seconds
2a, 2A-DC, DC

For full specification Click Here

CT Style DC current transducer,  Available up to 300 amps DC,  Bi Polar versions available.


Easy to install, Din rail mountable or screw on, witha a choice of analogue outputs.   IDEAL for battery and renewable energy applications.

2A-DC
2C, DC, 2C-DC

For full specification Click Here

CT Style split core DC current transducer,  Available up to 300 amps DC,  Bi Polar versions available.


Easy to install, Din rail mountable or screw on, witha a choice of analogue outputs.   IDEAL for battery and renewable energy applications.

2C-DC
AC Current Transducers and Switches, cs-, sc-, xd, cs-450, cs-451, cs450, cs451, cs-452, cs452, sc-550, sc550, sc-551, sc551, sc552, sc-552, sc575, sc-575, cs410. cs-410, sc510, sc-510, xd10, xd-10, xd19, xd-19

For full specification Click Here

 Features  CT Style Current Transducers & Switches  Easy and Economical to use  Moulded Case Insulation to 600VAC  Standard Ring Type or Split Core Versions  0-5VDC & 0-10VDC Output Versions  Loop Powered 4-20mA Output Version  Solid State Relay Output Versions  Most Versions Selectable Input Ranges  High Accuracy

AC Current Transducers & Switches
CEWE INSTRUMENT, Electrical Transducers - CEWE INSTRUMENTS, DI11, DI01, DI02, DU11, DU01, DU02, DU61, DU62, DP, DQ, DPQ, DF, DPF, DIF,

For full specification Click Here

In this section the wide range of CEWE INSTRUMENT BLUE MODULE Transducers is described - these are suitable for DIN-rail mounting. Owing to their excellent performance and high reliability (e.g. a MTBF of 40 years for current transducers) CEWE INSTRUMENT transducers are now used by power utilities and industry in over 20 European countries as well as in other parts of the world. The output from our transducers are, within certain limits, independent of load. The load limits are given on the data sheets. The load impendence is obtained by feedback of the output signal to the input of the amplifier. These transducer characteristics give great advantages among which the most important are:-  Measuring unit can be measured over relatively long distances.  Within the framework of permitted output signal loadings, several measuring or registration units can be connected simultaneously to the same transducer. No special tuning is required.  They have a wide range of applications because of there high accuracy and the fact that they are approved in accordance with interference tests IEC 255 -5 and -6, both for input and output signals.

Electrical Transducers - CEWE INSTRUMENTS
Signal Isolators and Converters, bob

For full specification Click Here
A din rail mounted four way AC current transducer. Accepting up to four inputs from the miniature split core current transformers supplied as a "kit" with the unit and giving four isolated analogue voltage signal outputs, either 0-5V DC or 0-10V DC. The maximum primary current possible is 50Amps which is compatible with the 10mm ID of the split core CT. The YW4 has individual pairs of terminals for the CT inputs, whilst the output channels share a common 0V rail. The YW4 requires a separate AC or DC supply voltage with isolation offered via an internal transformer or DC to DC converter.
FOUR WAY AC CURRENT TRANSDUCER 4 x 0.1-50 AMPS INPUTS yw4
FOX.ISC, signal converters

For full specification Click Here


WIDTH ONLY 17.MM
SINGLE INPUT, SINGLE OUTPUT
SINGLE INPUT, DUAL OUTPUT
SELECTABLE ANALOGUE SIGNAL INPUTS,
SELECTABLE ANALOGUE SIGNAL OUTPUTS

ALSO AVAILABLE
PT100 INPUTS, THERMOCOUPLE INPUTS
RESISTANCE & POTENTIOMETER INPUTS

FOX.ISC Signal Converters
Frequency to Analogue Converter, pxf, freqcon, pxf20, pxf-20

For full specification Click Here

PXF-20 A din rail mounted pulse frequency to analogue signal converter and isolator, only 22.5mm wide. Input frequency range selection is via a rotary switch on the front panel. Input source can be from either NPN, PNP or NAMUR selectable by the connecting to various input terminals. Output selection is also via a choice of wiring options on the output terminals. The front panel is also fitted with dual LED indication to give at a glance status, plus adjustable zero and span potentiometers. Freqcon The FREQCON is a frequency to analogue converter which can be programmed using a PC to perform any frequency to analogue converting function. The range of frequency input available is 0 - 1MHz and any offset can be introduced on the input . In addition a 21 point look-up table can be used to linearise non-linear inputs, with other linearisation functions such as square-root and custom polynomial also being available.The operational status of the unit is indicated by the front panel LED, a slow flashing indicating normal operation, a fast flash indicating an input failure, or hard off indicating a power supply failure. The unit can only be powered by any D.C. supply from 16 to 32 volts.

Frequency to Analogue Converter
Signal%20Isolators%20and%20Converters , MOD, MODU, MOD-U, MOD U, VOLTAGE TRANSDUCER, AC,

For full specification Click Here

An attractive modern design AC voltage transducer in a din rail mounted modular style housing of 1.5 modules width (27mm). The MOD-U voltage transducer is designed to measure AC voltage in a single phase system. It will convert the AC signal to a DC voltage output that is directly proportional to the input signal. The MOD-U is a self powered device (i.e. no auxiliary required). The output from the MOD-U is an isolated 0-10VDC.

MOD- U AC VOLTAGE TRANSDUCER
NMC Transducers

For full specification Click Here
Look at this for a great idea, do you ultimately need an analogue signal for your current measurement ? Many of the CTs feature a plug in transducer module option.

Just twist of the secondary terminal covers and remove the secondary terminal screws. Screw in the brass transformer to module connecting studs and plug in the NMC module.

Each NMC transducer block will give two different isolated analogue outputs. Also the secondary of the current transformer is repeated, if this repeat facility is not required the supplied shorting link must be left in situ. It is possible to generate 0-20mA and 0-10VDC without any auxiliary supply (self powered module version). Please note that the self powered versions can only be used on current transformers with an output of at least 2.5VA, if a 4-20mA signal is required in all cases an auxiliary supply is required, 24VDC, 110VAC or 230VAC.
NMC Transducers
PT100 Temperature to Analogue Converter, PXT10, PXT-10

For full specification Click Here

 Slim Modern Design  Input Range Selectable  2 or 3 Wire Selectable  Analogue output signal selectable  LED Indication  3.75KV Isolation  Zero & Span Adjustment A DIN rail mounted PT100 temperature to analogue signal converter and isolator, only 22.5mm wide. Input range and 2 or 3 wire selection is via connecting to various input terminals. Output selection is also via a choice of wiring options on the output terminals. The front panel is also fitted with dual LED indication to give at a glance status, plus adjustable zero and span potentiometers.

PT100 Temperature to Analogue Converter
Signal Isolators and Converters, PXU-20. Isocon, Dualcon, SC-VA, pxu20, scva, dualcon-3, dualcon-6, Isocon-3, isocon-6

For full specification Click Here

PXU-20 - Input & Output Selectable Analogue Signal Isolator & Converter  Slim Modern Design  Input & Output Selectable  LED Indication  3.75KV Isolation  Zero & Span Adjustment ISOCON - Isolating Signal Converters  Only 12.5mm Wide  Full 3-Port Isolation  Zero & Span Adjustment  High Accuracy  Wide Range of Inputs Available  AC & DC Power Supply Options DUALCON - Isolating Signal Converters - 1 Input, 2 Outputs  Only 17.5mm Wide  Full 4-Port Isolation  Zero & Span Adjustment  Two Isolated Outputs from One Input  Wide Range of Inputs Available  AC & DC Power Supply Options SC-VI-1 & SC-VI-2 - Isolating Signal Converters - 1 output & 2 outputs  22.5mm Wide  2KV Isolation  Zero & Span Adjustment  2x Selectable Outputs  5x Selectable Inputs  AC & DC Aux

Signal Isolator & Signal Converters