Din rail mounted or 8/11 pin plug in conductive probe level control relays for the control of maximum and/or minimum levels of conductive liquids.
Regulation of two levels “pump down” mode -The relay is energised when the high level probe is reached and deenergises when the level falls below the low level probe.
Regulation of two levels “pump up” mode -The relay is de-energised when the high level probe is reached and energises when the level falls below the low level probe.
Regulation of one level “pump down” mode selected - Connect the maximum and common terminals together. In this case a single probe only is used and the relay energises when the probe is immersed. Or in “pump up” mode the relay operation is reversed.
Prove relay test feature/override (Din rail versions only)- With probes connected the front selector switches can be used to control the relay providing a permanent “ON” or permanent “OFF”.
1. On conductive vessels and tanks the chassis can be used as the “Common” electrode. If the vessel is non conductive a third probe is required as the “Common”.
2. Probe cables up to a maximum of 100m need not be screened, above 100m screened cable is recommended. However, in any event it is not advisable to run the probe cables with power cables. When screened cable is used, the screen and the common should be connected together.
3. DC auxiliary supply units are available but not recommended as the probe supply is DC non isolated. DC on the probes runs a consequential risk of a possible electrolysis reaction, especially in solutions with a high mineral or contaminant contact. Whilst AC probes have a self cleaning effect.
Supply & Measuring
Nominal supply tolerance: ±15%
Isolation AC versions: Via transformer
Isolation level: 2KV AC between contacts, probes & supply
Isolation DC versions: No
Probe supply:
20V AC, (AC supply versions)
12VDC (DC supply versions)
Max probe current: 2mA
Power consumption: 3VA
Sensitivity range: Adjustable 4.7 to 100 KOhms
Response time: 100 mSec on make
Relay outputs:
Output contacts: SPCO 10Amps/250V AC1
Mechanical life: 30 Million ops
Electrical life: 200K ops at max rated load
General:
Operating temperature: -20°C to +65°C
Storage temperature: -20°C to +65°C
Max cable size: 4mm
CE marked: Yes
In accordance with:
EN61000-6-1: 2007
EN61000-6-3: 2007
EN61010-1: 2002
Housing material: Polycarbonate, Auto extinguishable to UL 94 V-0
TYPE
YWRW (Din rail SPCO)
11WRW (11 pin SPCO)
8WRW (8 pin SPCO)
8WRWO (8 pin SPCO)
YWR2W (Din rail DPCO)
11WR2W (11 pin DPCO)
COIL VOLTAGE
440VAC
415VAC
400VAC
380VAC
230VAC
110VAC
48VAC
24VAC
*12VDC
*24VDC
*48VDC
8WRWO has the Japanese standard pin out arrangement.