Product
group
GG
Response time: <400mSec
Warm up time: <15 mins
Output ripple: 1% peak full scale
Long term drift: +/- 0.25% per year non cumulative
Maximum load:
0-1mA 10 KOhm max
0-2.5mA 6 KOhm max
0-5mA 3 KOhm max
0-10mA 1.5 KOhm max
0-20mA & 4-20mA 750 Ohm max
Adjustment: Self powered voltage & current transducers have an adjustable span only. All other transducers have an adjustable zero & span
AC: 24 / 110 / 230 / 415V others on request
DC: 24 / 48 / 110V
Tolerance: +/- 20%
Consumption:
4VA / 4W
Combined Watt / VAr transducers 7VA / 7W
Directive 89/36/EEC:
Electrostatic discharge IEC801.2 (8KV)
Electromagnetic fields IEC801.3 level 3
Fast transient bursts IEC801.4 level 4
Surge withstand IEC255-5
Material: Grey ABS plastic with finger proof terminal covers
Isolation:
4KV rms 50Hz for 1 min (to IEC414) between input / output / case / auxiliary supply
1KV DC / 600VAC between outputs on combined Watt / VAr transducers
Mounting: 35mm Din rail (DIN-EN 50022)
CE Marked: Yes
See individual transducer pages for unit specific specification details
Receive updates about our offers, latests products and more, directly to your inbox