Product
group
DD
Din 96x48mm 5 digit digital panel meters, available with a wide choice of both DC and AC inputs, along with many process inputs. The meter can be specified with a choice of one of three outputs, one relay (non adjustable from the front) can be specified as latched or non latched, an isolated analogue output or RS485 MODBUS RTU. The meter utilises the latest microprocessor technology in both the setting and operation of the meter.
Programming & set up buttons can be specified with “Visible Buttons” on the front panel or “Discrete Buttons” behind the front screen. If not specified, meter will be supplied with “Discrete Buttons”
Relay programmable:
Low
High
Low (latched)
High (latched)
Number of setpoints: 1
Energisation functions:
Start delay
Energisation & de-energisation delay
Energisation latching
Hysteresis
Time delay adjustable: 0-9 mins 59.9 secs
Relay contact: SPDT 5A/230VAC, 10A/115VAC
Accuracy: ≤±0.1%of FS
Ripple: ≤±0.1% of FS
Response time: ≤100mSec (10-90% of input)
Output capability:
≥Voltage 1000 Ohm
Current into 600 Ohm max
Protocol: MODBUS RTU
Baud rate programmable: 1200 / 2400 / 4800 / 9600 / 19200 / 38400
Data bits: 8 bits
Parity programmable: Even, odd or none (with 1 or 2 stop bit)
Address programmable: 1-255
Distance: 1200 Metres
Terminal resistor: 150 Ohm at last unit
Measuring accuracy (VAA): ≤±0.1% FS ±1digit
Measuring accuracy (VAT): ≤±0.1% FS ±1digit
Measuring accuracy (VAD): ≤±0.04% FS ±1digit
Measuring accuracy (F): ≤±0.005% FS ±1digit
Measuring accuracy (SG): ≤±0.04% FS ±1digit
Measuring accuracy (PM): ≤±0.04% FS ±1digit
Measuring accuracy (RS): ≤±0.04% FS ±1digit
Measuring accuracy (T):
PT100:≤±0.1% FS ±1digit
Thermocouple: ≤±0.2% FS ±1digit
Measuring accuracy(RL): ≤±0.005% FS ±1digit
Sampling rate: 15 cycles / sec
Response time: ≤100mSec
Display: 20mm high red LEDs
Display range:
-19999 to 29999
(CS1-RL 0.0000 to 99999)
Decimal point: At any point or not at all
Over-range indication: “ovFL" displayed when input is over 120% of input range
Under-range indication: “-ovFL" displayed when input is under -20% of input range
Aux supply:
115/230 VAC ±15%, 50/60Hz
ADL: 20-56V AC/DC
ADH: 85-264VAC & 100-300VDC
Power consumption: 4.5 - 5VA
Excitation max current: 30mA
Operating temperature: 0-60°C
Operating relative humidity: 20-95% RH
Temperature coefficient: ≤100PPM / °C
Storage temperature: -10°C to +70°C
Dielectric strength: AC 2.0KV for 1 min between input, output/s power and case
Protection: IP54
The meter will be scaled exactly to your requirements
Programming & set up buttons can be specified with “Visible Buttons” on the front panel or “Discrete Buttons” behind the front screen. If not specified, meter will be supplied with “Discrete Buttons”.
For input voltages of between 1000V & 4000V either AC or DC an external “High Voltage Module” PCB must be used. The module has two voltage taps of 0-2000V & 0-4000V
Receive updates about our offers, latests products and more, directly to your inbox