Product
group
CC
The Foxtam Controls range of Din standard analogue meters are available as 48mm, 72mm and 96mm. The moving iron ammeters are fitted with the British standard x6 overload scale. However x5, x2 and no overload options are also readily available. The range, as standard, are supplied with 90° movements, 240° movements are also available to order. Also to note is that we can supply fully IP65 sealed meters, please see separate information tab below. Please contact the sales office for any assistance required.
The majority of meters are supplied with terminal covers as standard.
Standards: DIN43700, IEC51 and BS89
Sizes: Din 48mm, 72mm and 96mm
Types: AC Moving Iron & DC Moving Coil
Protection: IP52 (IP65 on request)
Insulation: 2kV for 1min
Temperature: Operating -25°C to +40°C
Construction: Pivot and jewel movement
Types: D48SD, D72SD, D96SD
Accuracy: Class 1.5
Burden:
Up to 5A movements 0.7VA
6A to 30A 1.2VA
40A and above 2.4VA
Ranges: 0.5/1/1.5/2/2.5/4/5/6/10/15/20/25/30/40/50/60/80/100 Amps
(D48SD only up to 40A)
1A & 5A movements also used as CT input
For instance D72SD/CT5 Scaled: 0-100A x6
Overscales:
British standard x6
On request x2, x5 or no overscale
Types: D48SD, D72SD, D96SD
Accuracy: Class 1.5
Burden: Max 6VA
Ranges: 150/300/500VAC (others on request)
Types: D48HZ, D72HZ, D96HZ
Accuracy: Class 1
Burden: 6mA
Ranges:
45-55Hz, 45-65Hz, 55-65Hz, 360-440Hz
45-65Hz standard range
Supply voltage must be specified 110/240/380/400/415/440V
Types: D48MC, D72MC, D96MC
Accuracy: Class 1.5
Burden: 80mV to 150mV volt drop depending on input current
Ranges:
Any input between 50 to 800uA and 1 to 800mA
Dedicated 4-20mA versions
Also:-
1/1.5/2/2.5/4/5/6/10/15/20/25/30/40/50A
D48MC only up to 30A
Scales: Special scales made as requested
Types: D48MC, D72MC, D96MC
Accuracy: Class 1.5
Burden: Approx 1mA
Ranges:
50mV to 1000V specify range required
D48MC up to 800V
Shunt input ranges available as standard i.e. 60mV
Scales: Special scales made as required
Types: D96PF (Self contained)
Accuracy: Class 1.5
Burden:
Current inputs 0.5VA
Voltage inputs 2VA
Inputs:
Current via 1Amp or 5Amp CT
Input Voltage direct 63VAC to 500VAC
System: 3P3W Balanced
Ranges: CAP 0.5 to 1 to IND 0.5
Types: D96WA
Accuracy: Class 1.5
Burden:
Current inputs 0.5VA
Voltage inputs 2VA
Inputs:
Current via 1Amp or 5Amp CT
Input Voltage direct 63VAC to 500VAC
Systems:
Single phase
3P3W Balanced
3P4W Balanced
3P3W Unbalanced
3P4W Unbalanced
Din 48mm: 45x45mm
Din 72mm: 68x68mm
Din 96mm: 92x92mm
FEATURES
DESCRIPTION
Din 72mm & 96mm analogue meters that are genuinely IP65 sealed, both from the front and also sealed to the panel via a gasket. The front seal is achieved by sealing the glass into the plastic bezel, whilst the adjusters for the adjustable red pointer, along with the zero adjuster are fitted into the glass with o-ring seals.
Ammeters are stocked in Din 72mm (Din 96mm on request) direct connected 2 Amps, 3 Amps, 4 Amps, 5 Amps, 6 Amps, 8 Amps, 10 Amps, 15 Amps, 20 Amps and 25 Amps. Also stocked are 5 Amps movement meters driven from a 5 Amp secondary current transformer (1 Amp secondary on request) and a corresponding scale will be fitted to match the current transformers primary. All ammeters have x6 overload movements and are fitted with the adjustable red pointer as standard. (On Request these can be supplied without)
Voltmeters are stocked in both Din 72mm and 96mm 0-500VAC. As standard they are not supplied with the adjustable red pointer option. (ARP available on request if required).
All meters are supplied as a kit which includes the IP65 panel gasket and a terminal cover.
ORDERING INFORMATION
TYPE
D72/IP65
D96/IP65
INPUT
*CT1A
*CT5A
DR
0-500V
RANGES
0.5A, 1A, 1.5A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 15A, 20A, 25A, 30A, 40A
RED POINTER
** ARP
* Specify current input range
** Insert ARP if Adjustable Red Pointer is required
DESCRIPTION
Foxtam Controls Phase Sequence Indicators (P .S.I) are suitable for a range of applications to indicate both the presence of all three phases and the correct sequence of those phases.
Incorrect phase connection will often cause serious damage to the motors of compressors, pumps, gen-sets, heating and ventilation equipment. Mobile generators, remote installations and shore to ship supplies are most vulnerable to such hazards and are, therefore, ideal applications for the Foxtam range.
The absence of a phase is indicated by a neon to identify the missing phase. The presence of all three phases in the correct sequence is indicated by the white neon. Incorrect phase sequence is indicated by a red neon.
MODELS
FE48PSI 48mm square
FE72PSI 72mm square
FE96PSI 96mm square
TECHNICAL DATA
Ratings:
Voltage 180 - 500V
Frequency 50/60Hz
Burden: 3VA maximum
Receive updates about our offers, latests products and more, directly to your inbox